The manufacturing of textile substrates for Mobiltech applications in terms of raw materials, construction, combination, functionality and recycling should be optimally aligned.

Increasing requirements for comfort and safety in cars/trucks result in a rising share of textiles in automotive applications. It ranges from rear shelves to seat covers and automotive wiring harness coverings. For composite constructions of trunk trims, rear shelves and floor units, mostly thermoplastic powders are used. Textile components in form of knitted or nonwoven distance fabrics invisibly provide a more comfortable seat-physiology in the seat construction.

New applications with textile components are absorbent nonwovens in batteries or fiber-optics in textile liners to illuminate specific areas (foot space, recessed grips, head/side liner) of the vehicle interior. Textiles and textilebased composites take over more functionalities in areas of shock absorption, acoustic insulation or heat protection.

Mobiltech

Product name Type Melting range Melt Flow Index Powder sizes Resistance to dry cleaning Hand iron Enzyme washing Washing resistance Steam resistance Stone-wash resistance Heat resistance Fusing conditions with flow-through-press Appearance
Pastedot Doubledot Powderdot Scatter Granules Lamination temperature Pneumatic pressure Time
ROWALIT® PBT 01-1 PBT 220 – 230 °C DSC 115 g / 10 Min. (MFI 230°C) 0 – 80 µm 160 °C 250 – 260 °C 3 – 5 N/cm² 10 – 12 Sek. White powder
ROWALIT® 200-2 Copolyamide 120 – 130 °C DSC 19 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 0 – 160 µm 100 – 500 µm very good no yes 95 °C very good yes 115 °C 140 – 160 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 200-7 Copolyamide 85 – 95 °C DSC 70 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 100 – 500 µm very good yes no 60 °C moderate no 80 °C 95 – 125 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 200-7A Copolyamide 85 – 95 °C DSC 90 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 100 – 500 µm good yes no 60 °C moderate no 80 °C 95 – 120 °C 3 – 5 N/cm² 10 – 20 Sek. White powder, Pellets
ROWALIT® 200-11 Copolyamide 105 – 115 °C DSC 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm very good no 60 °C good 100 °C 120 – 140 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 200-13 Copolyamide 120 – 130 °C DSC 23 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 0 – 200 µm 100 – 500 µm very good no no 80 °C moderate 110 °C 130 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 200-14 Biobased Products, Copolyamide 110 – 120 °C DSC 30 g / 10 Min. (MFI 160°C) 0 – 500 µm good no 60 °C 100 °C 120 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 200-16 Biobased Products, Copolyamide 110 – 120 °C DSC 40 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm very good 60 °C 100 °C 120 – 140 °C 3 – 5 N/cm² 10 – 18 Sek. White powder
ROWALIT® 200-27 Copolyamide 110 – 120 °C DSC 210 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm very good no 60 °C very good 150 °C 120 – 140 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 200-42 Copolyamide 105 – 125 °C DSC 40 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm very good no 60 °C moderate no 60 °C 130 – 150 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 200-63 Copolyamide 100 – 120 °C DSC 180 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm very good 60 °C good 90 °C 110 – 145 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 300-1/33-45 EVA 59 – 65 °C DSC 45 g / 10 Min. (MFI 190°C) 100 – 500 µm 40 °C 40 °C 75 – 82 °C 2 – 4 N/cm² 3 – 5 Sek.
ROWALIT® 400-1 Copolyester 118 – 123 °C DSC 30 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 160 µm
80 – 200 µm
0 – 160 µm 100 – 500 µm good no no 80 °C yes 100 °C 130 – 150 °C 3 – 5 N/cm² 10 – 12 Sek. White powder
ROWALIT® 400-2 Copolyester 110 – 115 °C DSC 15 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm good no no 60 °C fair 95 °C 130 – 150 °C 3 – 10 N/cm² 12 – 20 Sek. White powder
ROWALIT® 400-8 Copolyester 118 – 125 °C DSC 35 g / 10 Min. (MFI 160°C) 0 – 80 µm fair no no 60 °C fair 100 °C 125 – 145 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 400-14 Copolyester 177 – 186 °C DSC 110 g / 10 Min. (MFI 190°C) 0 – 80 µm good no 90 °C yes 140 °C 210 – 230 °C 3 – 10 N/cm² 12 – 20 Sek. White powder
ROWALIT® 400-SIT-18 Copolyester 110 – 120 °C DSC 30 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm good no 60 °C good 80 °C 110 – 135 °C 3 – 5 N/cm² 10 – 20 Sek. White powder
ROWALIT® 400-29 Biobased Products, Copolyester 110 – 120 °C DSC 34 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm good no no 60 °C no 100 °C 120 – 140 °C 3 – 5 N/cm² 10 – 12 Sek. White Powder
ROWALIT® 400-37M Copolyester 110 – 120 °C DSC 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm good no no 60 °C 100 °C 115 – 140 °C 3 – 5 N/cm² 10 – 20 Sek.
ROWALIT® 400-40 Copolyester 105 – 120 °C DSC 40 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 60 °C 100 °C 115 – 130 °C 3 – 5 N/cm² 10 – 20 Sek.
ROWALIT® BIOPOW 4000 Biobased Products, Copolyester 100 – 120 °C DSC 1 g / 10 Min. (MFI 190°C) 0 – 80 µm 80 – 200 µm 0 – 200 µm 0 – 300 µm
100 – 500 µm
130 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 400-41 Biobased Products, Copolyester 110 – 120 °C DSC 20 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm moderate no no 40 °C yes no 100 °C 125 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® BIOPOW 4042 Biobased Products, Copolyester 65 – 75 °C DSC 55 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm moderate yes no 40 °C 55 °C 80 – 110 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 400-44 Biobased Products, Copolyester 110 – 120 °C DSC 45 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm good no 60 °C good 100 °C 115 – 130 °C 3 – 5 N/cm² 10 – 20 Sek. White powder
ROWALIT® 500-1 TPU 90 – 105 °C DSC 4 g / 10 Min. (MFI 160°C) 100 – 500 µm 90 °C 100 – 120 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® 500-3 TPU 60 – 80 °C DSC 80 g / 10 Min. (MFI 160°C) 100 – 500 µm fair yes 60 °C 50 °C 75 – 80 °C 2 – 4 N/cm² 10 – 15 Sek. White powder
ROWALIT® 500-7 TPU 62 – 66 °C DSC 20 g / 10 Min. (MFI 160°C) 100 – 500 µm 75 – 85 °C 2 – 4 N/cm² 10 – 15 Sek.
ROWALIT® 500-9 TPU 130 – 145 °C DSC 35 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm very good no 95 °C very good 110 °C 135 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-SIT-23 TPU 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm good no 60 °C yes 90 °C 125 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-SIT-37 TPU 115 – 125 °C DSC 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm good 60 °C yes 90 °C 120 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-SIT-38 TPU 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 100 – 500 µm good no 60 °C yes 90 °C 125 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® BIOPOW 5038 Biobased Products, TPU 100 – 125 °C DSC 20 g / 10 Min. (MFI 160°C) 0 – 63 µm
0 – 80 µm
80 – 200 µm 0 – 500 µm good 60 °C 90 °C 125 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-50 TPU 6 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 100 – 500 µm good yes 60 °C no 60 °C 120 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-57 TPU 4 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 100 – 500 µm good no 60 °C no 90 °C 120 – 145 °C 2 – 4 N/cm² 12 – 20 Sek. White powder
ROWALIT® 500-59 TPU 125 – 140 °C DSC 30 g / 10 Min. (MFI 160°C) 0 – 80 µm 80 – 200 µm 100 – 500 µm good no 90 °C very good 110 °C 140 – 150 °C 3 – 5 N/cm² 12 – 20 Sek. White powder
ROWALIT® 600-1 Polypropylene 132 – 136 °C DSC 4 g / 10 Min. (MFI 190°C) 8 g / 10 Min. (MFI 230°C) 80 – 200 µm 0 – 200 µm 95 °C yes 115 °C 140 – 180 °C 3 – 6 N/cm² 12 – 30 Sek. Powder
ROWALIT® 690 Polypropylene 150 – 165 °C DSC 20 g / 10 Min. (MFI 190°C) 95 °C yes 150 °C 160 – 200 °C 3 – 6 N/cm² 12 – 25 Sek. Pellets, Powder
ROWALIT® FS-9 Flame-retardant Powders 110 – 120 °C DSC 95 °C 130 – 160 °C 3 – 5 N/cm² 10 – 20 Sek.
ROWALIT® FS-16 Flame-retardant Powders 110 – 120 °C DSC 95 °C
ROWALIT® H8 LDPE 107 – 110 °C DSC 8 g / 10 Min. (MFI 190°C) 60 °C 80 °C 130 – 150 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® H20 LDPE 104 – 108 °C DSC 20 g / 10 Min. (MFI 190°C) 60 °C 80 °C 130 – 150 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® H40 LDPE 102 – 106 °C DSC 40 g / 10 Min. (MFI 190°C) 60 °C 80 °C 130 – 150 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® H70 LDPE 100 – 104 °C DSC 70 g / 10 Min. (MFI 190°C) 60 °C 80 °C 130 – 140 °C 3 – 5 N/cm² 10 – 15 Sek. White powder
ROWALIT® H150 LDPE 98 – 102 °C DSC 150 g / 10 Min. (MFI 190°C) 40 °C 60 °C 120 – 130 °C 2 – 5 N/cm² 8 – 10 Sek. White powder
ROWALIT® N100-3 HDPE 130 – 135 °C DSC 4 g / 10 Min. (MFI 190°C) 0 – 80 µm very good no 95 °C yes 110 °C 170 – 180 °C 15 – 25 N/cm² 12 – 18 Sek. White powder
ROWALIT® N100-6 HDPE 128 – 130 °C DSC 6 g / 10 Min. (MFI 190°C) 0 – 80 µm 80 – 200 µm very good no 95 °C yes 110 °C 155 – 170 °C 10 – 20 N/cm² 12 – 18 Sek. White powder
ROWALIT® N100-20 HDPE 125 – 128 °C DSC 20 g / 10 Min. (MFI 190°C) 0 – 80 µm 80 – 200 µm 0 – 160 µm very good no 95 °C yes 110 °C 150 – 170 °C 10 – 20 N/cm² 10 – 12 Sek. White powder
ROWALIT® SS 8 Ionomer 95 – 100 °C DSC 6 g / 10 Min. (MFI 190°C) 80 °C 130 – 150 °C 3 – 5 N/cm² 10 – 20 Sek.